Key benefits

  • Low maintenance and easy inspection
  • Ultra silent design
  • Low energy consumption

Low maintenance and easy inspection

  • The S3000D has a spacious plenum (internal area) and easy access to inspect and maintain safely the unit interior components. Unrivalled comfort, while standing inside.
  • Upgrade the unit interior with ladder and platform for quick and save access to all unit components.
  • Access via large hinged door to optional internal walkway: no basin draining needed for unit interior or fill pack inspection.
  • The BACross II fill is telescopically supported; you can inspect and clean the core easily, sheet by sheet without dismantling. BACross II design reduces fouling.
  • The fill includes integrated drift eliminators conform to Eurovent standards.
  • Inspection of water distribution system (hot water basin and nozzles) possible outside the unit, during operation.
  • Optional distribution basin covers prevent debris collecting in the unit.
  • Self-cleaning cold water basin and fill above sloped basin to flush out dirt and debris.
  • Fans are easily accessible from the in- and outside
  • Optional clean out port helps remove silt and sludge from the cooling tower basin.
  • Removable suction strainer anti-vortex hood.
  • Optional sump sweeper piping prevents sediment collecting in the cold water basin. 
  • Various corrosion-resistant materials, including the unique Baltibond® Corrosion Protection System for guaranteed long service life.

Ultra silent design

  • S3000D units include low noise axial fans for minimal surrounding noise. To reduce noise even further, choose for Whisper Quiet fans.
  • Factory designed, tested and rated sound attenuation is available on air inlet and discharge to cut operation noise even further.
  • BACross II fill guides smoothly the water all the way into the basin without water splash noise.

Low energy consumption

  • Evaporative cooling for system-wide energy saving at lower operating temperatures.
  • Axial fan uses half the energy of similar centrifugal fan units.
  • Save pump kW! Less pump heat for this gravity water distribution system.
  • BACross II fill – factory-configured for maximum water/air contact and low air pressure drop for optimal cooling tower efficiency with limited energy consumption.
  • High efficiency fan motors

Unmatched hygiene control

  • Easy-clean and easy-inspect S3000D towers reduce hygiene risks from bacteria (eg Legionella) or biofilm inside.
  • Self-cleaning cold water basin and fill above sloped basin to flush out dirt and debris.
  • BACross II fill for reduced fouling and easy sheet by sheet cleaning without dismantling.
  • The fill includes integrated drift eliminators conform to Eurovent standards.
  • Combined inlet shields block sunlight to prevent biological growth in the tower, filter the air and stop water splashing outside.
  • Optional distribution basin covers prevent debris collecting in the unit.
  • Optional clean out port helps remove silt and sludge from the cooling tower basin.
  • Optional sump sweeper piping prevents sediment collecting in the cold water basin. 

Year round reliable operation

  • Top rated thermal performance - meets any flow and temperature needs.
  • Patented BACross II sheet fill with maximum air and water contact gives unbeatable heat transfer performance.
  • Various corrosion-resistant materials, including the unique Baltibond® Corrosion Protection System and FRP casing panels for guaranteed long service life.
  • Optional gear-drive system for more efficiency and less maintenance.

Want to use the S3000D cooling tower to cool your process water? Contact your local BAC representative.

 

 

S3000D characteristics

Cross flow, axial fan, induced draft


Capacity range

30 - 285 l/s


Water distribution

Gravity


Maximum entering water temperature

50°C standard fill
55°C with alternative fill


Typical applications

  • Medium to large HVAC and industrial applications
  • Replacement of field erected towers